WF100 cable is the UK’s most popular coaxial cable for TV and Satellite installations and is widely regarded as the highest quality coaxial cable in the market.
Not only is WF100 CAI-approved, it also meets the Cca s1b, d2, a2 CPR substandards required by BS6701 for the installation of telecommunications cables.
WF100 cable, or Webro Foam 100 coax cable is suitable for many applications, including low power video, video signal and broadband signals. It is also be used in high-frequency transmission, especially for transmitters and receivers, computers, radio and TV transmitters. WF100 is 4K TV & Ultra High Definition compatible.
Consisting of a 1.00mm solid plain copper conductor, foam polyethylene dielectric, copper foil tape and a plain copper wire braid. Argosy stocks in either PVC or LSF sheath material in black.
Conductor Material: Plain Annealed Copper
Conductor Stranding: Solid, 1/1.00mm
Dielectric Material: Foam Polyethylene (FPE)
Dielectric Diameter: 4.60mm ± 0.10
Screening 1: Overall Plain Copper Foil
Screening 1 Coverage: > 100%
Screening 2: Plain Copper Wire Braid
Screening 2 Coverage: > 55% ± 3
Sheath Material: Polyvinyl Chloride (PVC)
Sheath Colour: Black
Mechanical Characteristics
Overall Diameter: 6.65mm ± 0.30mm
Temperature Range: Fixed -15°C to +70°C, Flexing -5°C to +70°C
Bend Radius: 10 x Overall Diameter
Weight: 51kg/km
Electrical Characteristics
Inner Conductor DC Resistance: ≤ 26.0 Ω/km @ 20°C
Outer Conductor DC Resistance: ≤ 15 Ω/km @ 20°C
Characteristic Impedance: 75 Ω ± 3Ωm
Nominal Capacitance: 54 pF/m
Velocity of Propagation: 82%
Attenuation @ 20°C
Frequency (MHz): Attenuation (per 100m):
5 1.60 dB
50 4.60 dB
100 6.50 dB
200 9.50 dB
460 15.0 dB
860 19.5 dB
1000 21.5 dB
1750 29.0 dB
2150 32.5 dB
Return Loss @ 20°C
Frequency (MHz): Return Loss:
5MHz – 30MHz ≥ 23 dB
30MHz – 470MHz ≥ 23 dB
470MHZ – 862MHz ≥ 20 dB
862MHZ – 2150MHz ≥ 18 dB
Certifications & Standards:
CAI Certification: CAI 0116F
Screening Class: BS EN 50117
Flame Retardancy: BS EN 60332-1-2
RoHS 3 Compliant: Yes
REACH Compliant: Yes
UKCA CPR Classification: Eca to BS EN 50575:2014+A1:2016